Lagoon Pump Inspection Record
Lagoon work carries dangers that ordinary shop work does not. Manure gases can kill quickly, and a pump that seems to need just a quick look can pull a person into a fatal mistake. Plan the inspection around the hazards first and the pump second.
Hazards before everything else
Gas from stored manure, including hydrogen sulfide, can reach harmful levels with little warning, especially when the liquid is agitated or the pump is being moved. Never enter a pit, tank, or confined space to retrieve a pump or tool, and do not lean over an enclosed opening. If the pump stops or someone falls in, do not go in after them; call emergency services and use rescue methods that do not require entry. Keep people and children away from the lagoon edge. The CDC NIOSH agriculture pages discuss manure gas and confined space dangers.
Be extra careful during agitation and pump-out, since gas release is greatest then. Make sure ventilation is adequate for any building that connects to a pit, and follow your operation's safety plan.
What to inspect on the pump and system
Disconnect and lock out power before any physical contact, including the electrical supply at the panel. Pumps in or near liquid manure involve high voltage and wet conditions, so electrical faults are a serious risk. Have a qualified electrician look at damaged cords, junction boxes, and control panels.
For a pump on a tractor PTO, check the shield and driveline. See the PTO safety and shield inspection form. Then look for:
- Leaks or wet spots at seals, couplings, and hose connections.
- Abrasion or cuts on discharge hoses and suction lines.
- Bearing noise or heat, and unusual vibration.
- Worn impeller or chopper blades, which show up as reduced flow or plugging.
- Corroded mounting hardware, brackets, and chains.
Solids, rope, and plastic can wrap and jam a pump. If flow drops, shut down fully and follow lockout before clearing anything.
Records and replacement parts
Write down date, hours, flow and pressure observations, what you saw, and what was done. Note the pump model and serial number and the part numbers for seals, wear plates, impellers, and bearings from the manufacturer's parts catalog. Compare with past entries to spot gradual change. For similar equipment, the slurry tanker maintenance checklist shares many of these points.
Salvage parts can work for housings and brackets if you check for cracks and match the model range, but seals, hoses, shields, and electrical parts are better bought new because failure is hazardous.
When unsure, stop and call the dealer or a qualified service technician. Nothing about a lagoon pump is worth a risk to a person.
General information only. Follow the operator's manual, your dealer's service guidance and the parts catalog for your specific machine.
Sources: CDC NIOSH Agriculture · OSHA Agriculture · AgriSafe